深圳波紋電阻設(shè)計(jì)原理 波紋電阻材質(zhì)介紹 波紋電阻特點(diǎn)有哪些 威源供
被漆功率瓷管電阻器Coated High Power Ceramic Tube Resistors HR series
■過(guò)負(fù)荷能力強(qiáng),熱穩(wěn)定性好,使用壽命長(zhǎng)Good overload and heat-durability capacity,the use life is longer then the others.
■表面涂漆為綠色不然性面漆 The resistors surface is
coated in green.
阻值及阻值誤差 Resistance and Resistance tolerance
|
阻值允許誤差 Resistance tolerance ±5% (J) |
阻值將根據(jù)如下表格中所施加的電壓值后進(jìn)行測(cè)量。Resistance shall be measured using the applied voltage values of the following table.
|
||||||
溫度系數(shù) Temperature coefficient |
±300ppm |
在常溫及常溫+100℃時(shí)分別測(cè)量電阻并計(jì)算每度的阻值變化率。Test the resistance value at normal temperature and normal temperature added 100℃,calculate per℃ resistance value change rate . |
||||||
額定功率 Power rating load |
△R/R≦± (1%+0.05Ω) 表面溫升(temperature) 350℃Max. |
在受試電阻上加30分鐘的額定電壓the power rating is applied to the resistor kept horizontally for 30 min. |
||||||
短時(shí)間過(guò)負(fù)荷 Short-time overload |
△R/R≦± (2%+0.05Ω) |
10倍額定電壓測(cè)試5秒。At 10× rated voltage for 5 seconds. |
||||||
絕緣阻值 Insulation resistance |
≥100MΩ |
DC500V |
||||||
絕緣電壓 Dielectric withstanding voltage |
無(wú)火花、燒損或絕緣破壞等異常現(xiàn)象。 Without damage by flash-over, fire. or breakdown, etc. |
≥AC2000V,60秒(sec.) |
||||||
端子強(qiáng)度 Terminal strength |
無(wú)機(jī)械損傷 no evidence of mechanical damage |
張力(Pull):196N , 30± 5 秒seconds |
||||||
電阻體強(qiáng)度 Resistor strength |
無(wú)機(jī)械損傷 no evidence of mechanical damage |
294N,30± 5秒seconds |
■耐候性Environmental charactaristics
特性 Characteristics |
規(guī)格值 Standards |
測(cè)試方法 Test methods |
耐熱性 Heat resistance |
△R/R≦± (1%+0.05Ω) |
在375±10℃錫爐中浸2~3秒 Immerge into 375±10℃ tin stove for 2~3 seconds. |
熱沖擊 Thermal shock |
△R/R≦± (2%+0.05Ω) |
-55℃/30分鐘(min.)→+25℃/15分鐘(min.)→+125℃/30分鐘(min.)→+2515分鐘(min. 共5個(gè)循環(huán) total 5 cycles. |
耐溫負(fù)荷壽命 Power rating load |
△R/R≦± (5%+0.05Ω) |
在溫度為40±2℃,相對(duì)濕度為90~95%的恒溫恒濕箱中,施加額定電壓或比較大工作電壓(取較小者)共1000小時(shí)(通1.5小時(shí),斷0.5小時(shí))。Overload rated voltage or Max.working voltage (get the lower) for 1000 hours (1.5 hours on and half-hour off ) at the 40±2℃ and 90~95% relative humidity. |
耐溫負(fù)荷壽命 Load life in heat |
△R/R≦± (5%+0.05Ω) |
在70±2℃恒溫恒濕箱中施加額定電壓或比較大工作電壓(取較小者)1000小時(shí)(通1.5小時(shí),斷0.5小時(shí))。Overload rated voltage or Max.working voltage (get the lower ) for 1000 hours (1.5 hours on and half-hour off) at the 70±2℃. |
備注Note:具體規(guī)格尺寸可以根據(jù)客戶的需求制作,同時(shí)也可以制作一管多個(gè)阻值,也可按客戶要求取消固定支架。We can according to customer’s requirement to customize the specification and dimension, also can produce multiple resistance values of one ceramic tube or cancel the fixed plank |